Bozhko V. P. Method for energy scale calibration of the scintillation detector at registration of recoil protons / V. P. Bozhko, A. N. Vodin, S. N. Olejnik, G. E. Tuller // Functional Materials. - 2009. - 16, № 2. - С. 122-125. - Бібліогр.: 12 назв. - англ.A method of the energy scale calibration of scintillation detectors in the proton energy range 1 to 14 MeV has been developed. The method is based on comparison of maxima of calculated and experimental spectra of recoil protons obtained due to scattering of quasi-monochromatic neutrons from the <$E roman {d(T,n) sup 4 He}> and <$E roman {d(T,n) sup 3 He}> reactions on hydrogen nuclei contained in the converter. The energy scale calibration of a CsI(Tl) detector has been carried out using the <$E roman {d(T,n) sup 4 He}> reaction. It is found that the proton energy dependence of the detector specific light yield has a square polynomial form. Індекс рубрикатора НБУВ: В381.592