Наукова періодика України Naukovyi visnyk Natsionalnoho Hirnychoho Universytetu


Vytvytskyi I. I. 
Calculation of distance between elastic-rigid centralizers of casing / I. I. Vytvytskyi, M. V. Seniushkovych, I. P. Shatskyi // Науковий вісник Національного гірничого університету. - 2017. - № 5. - С. 29-35. - Режим доступу: http://nbuv.gov.ua/UJRN/Nvngu_2017_5_7
Purpose. Formulation and solution to the problem of rational centering of the casing under the complex configuration of well axis using elastic-rigid centralizers. Methodology. The model of the "casing-well" system is under consideration. In the simulation system, the column in the hole is loaded by two and pressure forces caused by the complex configuration of the well axis and distributed between the centering devices. The influence of structural peculiarities of the cyclically symmetric "bow" type centralizers on their rigidity and toughness characteristics has been taken into account. The solution of the problem will be considered found when the allowable minimum value of a gap in the "casing-well-wall" system is provided. Findings. The dependencies to determine the distance between the centralizers and allowable gap have been determined on the basis of the solution of the problem of rod bending on the elastic-rigid supports. With the increase in zenith angle due to increased transverse component of gravity, the distance between centralizers reduces. Moreover, for small zenith angles it is even smaller, due to greater downforce. For large zenith angle as well as for large pressing forces, their influence on the distance between the centering devices is offset due to activation of the stop. In particular, it was determined that the stop of a centralizer provided it has sufficient strength can guarantee the required gap at considerable loads on the column. The results of the research have been approved by the engineering calculations for specific sizes of casing and well. Originality. New dependencies to calculate the distance between the elastic-rigid centralizers used in casing the well taking into consideration groups of factors that determine the wellbore profile and centralizer specifications have been established. Practical value. The obtained results provide for optimizing the exact number and intervals of equipping the casing with centering devices and thereby avoid the formation of dead zones in the annulus. This will give the opportunity to achieve high-quality cement job and make casing of the well of any configuration reliable and time-proof.
  Повний текст PDF - 2.102 Mb    Зміст випуску     Цитування публікації

Цитованість авторів публікації:
  • Vytvytskyi I.
  • Seniushkovych M.
  • Shatskyi I.

  • Бібліографічний опис для цитування:

    Vytvytskyi I. I. Calculation of distance between elastic-rigid centralizers of casing / I. I. Vytvytskyi, M. V. Seniushkovych, I. P. Shatskyi // Науковий вісник Національного гірничого університету. - 2017. - № 5. - С. 29-35. - Режим доступу: http://nbuv.gov.ua/UJRN/Nvngu_2017_5_7.

      Якщо, ви не знайшли інформацію про автора(ів) публікації, маєте бажання виправити або відобразити більш докладну інформацію про науковців України запрошуємо заповнити "Анкету науковця"
     