Наукова періодика України Semiconductor physics, quantum electronics & optoelectronics


Lopatynskyi A. 
Comparative analysis of response modes for gold nanoparticle biosensor based on localized surface plasmon resonance / A. Lopatynskyi, O. Lopatynska, V. Chegel // Semiconductor physics, quantum electronics & optoelectronics. - 2011. - Vol. 14, № 1. - С. 114-121. - Режим доступу: http://nbuv.gov.ua/UJRN/MSMW_2011_14_1_21
The theoretical comparison of possible response measurement techniques for a biosensor based on localized surface plasmon resonance (LSPR) in spherical Au nanoparticle was made. The methods for measuring LSPR response considered differed in the treatment of the change of light extinction spectrum along the wavelength and extinction coordinate axes upon the formation of dense biomolecular monolayer on the surface of the sensitive element. In addition, the transformation of the extinction LSPR band with increase of the nanoparticle radius from 5 to 125 nm was investigated towards the optimization of LSPR response for dipolar and quadrupolar LSPR extinction peaks. A novel method for the measurement of wavelength shift <$E H sub top sup +> was introduced and demonstrated to be more effective for estimation of the LSPR biosensor response as compared to commonly measured extinction peak shift <$E DELTA lambda sub max>. These techniques were proved to produce maximal LSPR response when large-size Au nanoparticle (with a radius of 125 nm) was used as a sensitive element of biosensor. The preferable mode of extinction difference measurement turned out to be <$E V sub right>, which is carried out at a wavelength of the extreme extinction spectrum derivative on a right slope of the LSPR peak. For this method, optimal nanoparticle radii were found to be about 40 nm for the dipolar LSPR peak and near 100 - 105 nm for the quadrupolar one.
  Повний текст PDF - 405.135 Kb    Зміст випуску     Цитування публікації

Цитованість авторів публікації:
  • Lopatynskyi A.
  • Lopatynska O.
  • Chegel V.

  • Бібліографічний опис для цитування:

    Lopatynskyi A. Comparative analysis of response modes for gold nanoparticle biosensor based on localized surface plasmon resonance / A. Lopatynskyi, O. Lopatynska, V. Chegel // Semiconductor physics, quantum electronics & optoelectronics. - 2011. - Vol. 14, № 1. - С. 114-121. - Режим доступу: http://nbuv.gov.ua/UJRN/MSMW_2011_14_1_21.

    Додаткова інформація про автора(ів) публікації:
    (cписок формується автоматично, до списку можуть бути включені персоналії з подібними іменами або однофамільці)
  • Лопатинський Андрій Миколайович (фізико-математичні науки)
  • Чегель Володимир Іванович (фізико-математичні науки)
  •   Якщо, ви не знайшли інформацію про автора(ів) публікації, маєте бажання виправити або відобразити більш докладну інформацію про науковців України запрошуємо заповнити "Анкету науковця"
     
    Відділ інформаційно-комунікаційних технологій
    Пам`ятка користувача

    Всі права захищені © Національна бібліотека України імені В. І. Вернадського